Fobas Bunker Alert! Galveston Area Fuel Problems

2084

  • Bunker fuel alert issued after FOBAS found HFO in a number of vessels facing operational issues in Galveston.
  • The Contaminated Fuel in question have met the Table 2 of ISO 8217 guidelines but further testing is suggested.
  • Initial tests suggest the presence of certain fatty acids which causes engine damages.
  • Acid number results show a range between 0.40mgKOH/g to 0.90mgKOH/g.

A number of vessels are facing operational problems after bunkering HFO from Galveston and nearby ports in the US Gulf. Problems encountered by ships include blocked fuel filters, sticking of fuel injection pumps as well as damage to fuel pumps, says a report published on FOBAS website.

The Contaminated Fuel

The fuels in question have been bunkered against RMG380 grade and subsequent analysis indicated that they met the specification limits of Table 2 of ISO 8217. Acid number results have been determined to be in the range 0.40mgKOH/g to 0.90mgKOH/g. Further investigation on these fuels is still ongoing but initial results from FTIR and GC-MS testing suggests the presence of certain fatty acids which should not be present in marine fuels and have been linked to sticking and damaged fuel pump components in the past.

Any contamination may be at low levels and not easily detectable without in-depth testing. However, according to the latest version of ISO8217, for the fuel to be within specification, it must be free from any material at a concentration that causes the fuel to be unacceptable for use no matter the concentration.

Investigation on process

Until the investigation into the quality of the mentioned fuels have been completed, for any vessels bunkering in Galveston and nearby ports we recommend:

  • Particular attention is paid to the terms of the bunker requisition and specifically mention that the fuel must exclude any anomalous components.
  • Acid Number of the fuel is determined.
  • Close attention is paid to the fuel pump and injector performance during the use of fuels bunkered from Galveston and nearby ports.

To ensure that representative samples of the fuel are obtained, it is also important that correct sampling procedures are followed and any operational problems documented.

Did you subscribe for our daily newsletter?

It’s Free! Click here to Subscribe!

Source: Lloyd’s Register