Accidental Main Engine Shutdown Activation led To Grounding

1478

Staff on an up-bound tanker in a river waterway decided to anchor the vessel just below the lock to wait for traffic ahead to clear. While it was anchoring the vessel lost propulsion.

Incident

Staff on an up-bound tanker in a river waterway decided to anchor the vessel just below the lock to wait for traffic ahead to clear. While it was anchoring the vessel lost propulsion.

The Master immediately contacted the engine room crew, who requested that propulsion control be transferred to the engine room. This would allow them to attempt to restart the engine.

As the engine room crew were working to restart the main engine, the port bow anchor was remotely released from the bridge.

Despite these efforts, the vessel grounded. Although the main engine was soon restarted and propulsion control was transferred back to the bridge, attempts to free the vessel under power were unsuccessful. Two days later the vessel was refloated with the assistance of two tugs and towed to a nearby dock. Subsequent underwater inspection showed there was no apparent damage to the vessel.

Investigation

During investigation, it was found that

  1. The investigation found that the main engine shutdown feature on the touchscreen integrated alarm monitoring and control system had inadvertently been activated.
  2. Tests showed that the touchscreen was reactive to a variety of inputs – including the telephone cord situated next to it. When the main engine shutdown button was activated on the touchscreen, a generic and ambiguous system status message appeared on the screen. 
  3. The message did not specify that the engine was about to shut down, nor did it indicate how the shutdown was activated or from where (bridge, engine room, emergency stop etc).

Action taken

A plastic cover was placed over the touchscreen to prevent another inadvertent shutdown. After a thorough review, the equipment manufacturer disabled the main engine shutdown function on the touchscreen and the plastic cover was removed. In case of an emergency, the main engine can still be shut down from the bridge via the traditional shutdown button.

Lesson learnt

  • In order to use shipboard equipment effectively, crews must know how to operate that equipment during routine and emergency situations. 
  • It was especially important for crew members to familiarise themselves with the sensitivity level of the screen and the lack of any confirmation message after any action was taken using it.

Did you subscribe to our daily newsletter

It’s Free! Click here to subscribe!

Source: nautinst.org